4.7 Article

Evaluating the potential and limitations of double-spiking species-specific isotope dilution analysis for the accurate quantification of mercury species in different environmental matrices

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 390, Issue 2, Pages 655-666

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-007-1598-z

Keywords

mercury speciation; species-specific isotope dilution; environmental matrices

Ask authors/readers for more resources

A new double-spiking approach, based on a multiple-spiking numerical methodology, has been developed and applied for the accurate quantification of inorganic mercury (IHg) and methylmercury (MeHg) by GC-ICPMS in different environmental matrices such as water, sediments and a wide range of biological tissues. For this purpose, two enriched mercury species ((MeHg)-Me-201 and (IHg)-I-199) were added to the samples before sample preparation in order to quantify the extents of the methylation and demethylation processes, and thereby correct the final species concentrations. A critical evaluation of the applicability of this methodology was performed for each type of matrix, highlighting its main advantages and limitations when correcting for the conversion reactions of the species throughout the whole sample preparation procedure. The double-spike isotope dilution (DSIDA) methodology was evaluated by comparing it with conventional species specific isotope dilution (IDA) when analysing both certified reference materials and environmental samples (water, biotissues and sediment). The results demonstrate that this methodology is able to provide both accurate and precise results for IHg and MeHg when their relative concentrations are not too different (ratio MeHg/IHg>0.05), a condition that holds for most natural waters and biotissues. Significant limitations on the accurate and precise determination of the demethylation factor are however observed, especially for real sediment samples in which the relative concentrations of the species are substantially different (ratio MeHg/IHg<0.05). A determination of the sources of uncertainty in the methylation/demethylation factors has demonstrated that the accurate and precise measurement of the isotope ratios in the species involved in the transformations is crucial when quantifying the extents of these reactions. Although the double-spike methodology is established as a reference approach that permits the correction of most analytical biases and the accurate quantification of Hg species, some limitations have been identified for the first time in this work.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available