4.6 Article

Evaluation of a new optical biometry device for measurements of ocular components and its comparison with IOLMaster

Journal

BRITISH JOURNAL OF OPHTHALMOLOGY
Volume 98, Issue 9, Pages 1277-1281

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/bjophthalmol-2014-305150

Keywords

-

Categories

Funding

  1. Foundation of Wenzhou City Science & Technology Bureau [Y20110045, Y20120176]
  2. innovative project of School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University [YNCX201302]
  3. health Bureau of Zhejiang Province [2012KYB135]
  4. Scientific Research Fund of Zhejiang Provincial Education Department [Y201223147]

Ask authors/readers for more resources

Objective To assess the reliability of ocular component measurements with a new optical biometry device (AL-Scan; Nidek) and compare these measurements with those of the IOLMaster (Carl Zeiss Meditec) in patients with cataract. Methods Sixty-eight cataractous eyes of 68 patients were included in the prospective study. To assess AL-Scan repeatability and reproducibility, central corneal thickness, anterior chamber depth (ACD), keratometry (K) over 2.4 mm and 3.3 mm diameter, axial length (AL), white to white (WTW), and pupil distance (PD) values were measured by two operators. ACD, K, AL and WTW were also measured with the IOLMaster to investigate the level of agreement. Calculations of intraocular lens (IOL) power were compared between the two devices. Results AL-Scan measurements were highly repeatable and reproducible, except for WTW and PD. Bland-Altman analysis showed good agreement between devices for AL, ACD and most K values. Compared with the IOLMaster, AL-Scan-derived K values using a diameter of 2.4 mm showed a narrower 95% limit of agreement (LoA) than those obtained with a diameter of 3.3 mm. However, poor agreement of WTW measurements was found. The 95% LoAs between devices for IOL calculations were smaller when based on AL-Scan K measurements using a diameter of 2.4 mm rather than 3.3 mm. Conclusions The repeatability and reproducibility of AL-Scan was excellent for all parameters, except WTW and PD. Excluding WTW, good agreement was found between the AL-Scan and IOLMaster. The 2.4-mm diameter K value may be the most reliable choice for calculation of IOL power with the AL-Scan.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available