4.1 Article

Significance of intraoperative motor function monitoring using transcranial electrical motor evoked potentials (MEP) in patients with spinal and cranial lesions near the motor pathways

Journal

BRITISH JOURNAL OF NEUROSURGERY
Volume 23, Issue 1, Pages 48-55

Publisher

TAYLOR & FRANCIS LTD
DOI: 10.1080/02688690802563349

Keywords

Intraoperative monitoring; spinal tumour; cerebral tumour; motor evoked potentials; motor pathways

Ask authors/readers for more resources

Intraoperative motor evoked potential (MEP) monitoring in patients with spinal and cranial lesions is thought to be a valuable tool for prevention of postoperative motor deficits. Aim of this study was to investigate its diagnostic value in a spinal and a cranial patient group. Ninety-six patients, 31 with spinal and 65 with intracranial lesions, were studied. Transcranial stimulation was performed with a high-frequency electrical train stimulation using two subdermal needle electrodes. MEPs were recorded from the pathology-related muscles. Decreasing amplitudes of 50% or more, increasing stimulus intensities of 20% or more or increased latencies were taken as warning criteria. MEP recording was possible in 90% of the spinal and 98% of the cranial group. With two further exclusions, 28 patients of the spinal and 62 of the cranial group were analyzed. We saw a temporary maximum amplitude reduction of 50% or more and an increase in stimulation intensity of 20% or more in 8 spinal and 29 cranial patients. Five of the spinal and nine of the cranial patients deteriorated in motor function postoperatively. One patient with normal MEP monitoring showed a temporary motor weakness postoperatively. Latencies were normal in all patients. Given both warning criteria, intraoperative MEP changes had a sensitivity of 83%/ 100% and a specificity of 86%/ 62% (spinal/ cranial group). The positive predictive value of MEP changes for postoperative motor function deterioration was 63%/ 31%, and the negative predictive value was 95%/ 100%. Transcranial electrical monitoring of MEP is a practicable and safe method. However, there are many events, which can cause amplitude changes of MEP independent from surgical manipulations. Although sensitivity is high for both groups, this results in a moderate specificity for the cranial group and a low positive predictive value for both groups.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.1
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available