4.8 Article

Use of Fast HPLC Multiple Reaction Monitoring Cubed for Endogenous Retinoic Acid Quantification in Complex Matrices

Journal

ANALYTICAL CHEMISTRY
Volume 87, Issue 6, Pages 3222-3230

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/ac504597q

Keywords

-

Funding

  1. University of Maryland, Baltimore Department of Pharmaceutical Sciences New Faculty Start-Up funds
  2. Federal funds from the National Institute of Allergy and Infectious Diseases [HHSN272202000046C]

Ask authors/readers for more resources

Retinoic acid (RA), an essential active metabolite of vitamin A, controls numerous physiological processes. In addition to the analytical challenges owing to its geometric isomers, low endogenous abundance, and often localized occurrence, nonspecific interferences Observed during liquid chromatography (LC) multiple reaction monitoring (MRM) quantification methods have necessitated lengthy chromatography to obtain accurate quantification free of interferences. We report the development and validation of a fast high performance liquid chromatography (HPLC) multiplexing multiple reaction monitoring cubed (MRM3) assay for selective and sensitive quantification of endogenous RA from complex matrices. The fast HPLC separation was achieved using an embedded amide C18 column packed with 2.7 mu m fused core particles which provided baseline resolution of endogenous RA isomers (all-trans-RA, 9-cis-RA, 13-cis-RA, and 9,13-di-cis-RA) and demonstrated significant improvements in chromatographic efficiency compared to porous particle stationary phases. Multiplexing technology further enhanced sample throughput by a factor of 2 by synchronizing parallel HpLC systems to a single mass Spectibmeter. The fast HPLC multiplexing MRM3 assay demonstrated enhanced selectivity for endogenous RA quantification in coMplex matrices and had comparable analytical performance to robust, validated LC-MRM methodology for RA. quantification. The quantification of endogenous RA using the described assay was validated on a number Of mouse tissues, nonhuman primate tissues, and human plasma samples. The combined integration of fast HPL,C, MRM3, and multiplexing yields an analysis workflow for essential low-abundance endogenous metabolites that has enhanced selectivity in complex matrices and increased throughput that will be useful in efficiently interrogating the biological role of RA in larger study populations.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available