4.5 Article

Diode laser-based cavity ring-down instrument for NO3, N2O5, NO, NO2 and O-3 from aircraft

Journal

ATMOSPHERIC MEASUREMENT TECHNIQUES
Volume 4, Issue 6, Pages 1227-1240

Publisher

COPERNICUS GESELLSCHAFT MBH
DOI: 10.5194/amt-4-1227-2011

Keywords

-

Funding

  1. NOAA

Ask authors/readers for more resources

This article presents a diode laser-based, cavity ring-down spectrometer for simultaneous in situ measurements of four nitrogen oxide species, NO3, N2O5, NO, NO2, as well as O-3, designed for deployment on aircraft. The instrument measures NO3 and NO2 by optical extinction at 662 nm and 405 nm, respectively; N2O5 is measured by thermal conversion to NO3, while NO and O-3 are measured by chemical conversion to NO2. The instrument has several advantages over previous instruments developed by our group for measurement of NO2, NO3 and N2O5 alone, based on a pulsed Nd:YAG and dye laser. First, the use of continuous wave diode lasers reduces the requirements for power and weight and eliminates hazardous materials. Second, detection of NO2 at 405 nm is more sensitive than our previously reported 532 nm instrument, and does not have a measurable interference from O-3. Third, the instrument includes chemical conversion of NO and O-3 to NO2 to provide measurements of total NOx (=NO + NO2) and Ox (=NO2 + O-3) on two separate channels; mixing ratios of NO and O-3 are determined by subtraction of NO2. Finally, all five species are calibrated against a single standard based on 254 nm O-3 absorption to provide high accuracy. Disadvantages include an increased sensitivity to water vapor on the 662 nm NO3 and N2O5 channels and a modest reduction in sensitivity for these species compared to the pulsed laser instrument. The in-flight detection limit for both NO3 and N2O5 is 3 pptv (2 sigma, 1 s) and for NO, NO2 and O-3 is 140, 90, and 120 pptv (2 sigma, 1 s) respectively. Demonstrated performance of the instrument in a laboratory/ground based environment is better by approximately a factor of 2-3. The NO and NO2 measurements are less precise than research-grade chemiluminescence instruments. However, the combination of these five species in a single instrument, calibrated to a single analytical standard, provides a complete and accurate picture of nighttime nitrogen oxide chemistry. The instrument performance is demonstrated using data acquired during a recent field campaign in California.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available