4.6 Article

A robust linear regression based algorithm for automated evaluation of peptide identifications from shotgun proteomics by use of reversed-phase liquid chromatography retention time

Journal

BMC BIOINFORMATICS
Volume 9, Issue -, Pages -

Publisher

BMC
DOI: 10.1186/1471-2105-9-347

Keywords

-

Funding

  1. Ohio State University
  2. National Institutes of Health [CA107106, CA101956]
  3. V Foundation
  4. Leukemia & Lymphoma Society
  5. Pacific Northwest National Laboratory (PNNL) in Richland, Washington
  6. NIH National Center for Research Resources [RR18522]
  7. Wiley Environmental Molecular Science Laboratory
  8. U. S. Department of Energy's [DE-AC05-76RL0 1830]
  9. Office of Biological and Environmental Research
  10. Battelle Memorial Institute

Ask authors/readers for more resources

Background: Rejection of false positive peptide matches in database searches of shotgun proteomic experimental data is highly desirable. Several methods have been developed to use the peptide retention time as to refine and improve peptide identifications from database search algorithms. This report describes the implementation of an automated approach to reduce false positives and validate peptide matches. Results: A robust linear regression based algorithm was developed to automate the evaluation of peptide identifications obtained from shotgun proteomic experiments. The algorithm scores peptides based on their predicted and observed reversed-phase liquid chromatography retention times. The robust algorithm does not require internal or external peptide standards to train or calibrate the linear regression model used for peptide retention time prediction. The algorithm is generic and can be incorporated into any database search program to perform automated evaluation of the candidate peptide matches based on their retention times. It provides a statistical score for each peptide match based on its retention time. Conclusion: Analysis of peptide matches where the retention time score was included resulted in a significant reduction of false positive matches with little effect on the number of true positives. Overall higher sensitivities and specificities were achieved for database searches carried out with MassMatrix, Mascot and X!Tandem after implementation of the retention time based score algorithm.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available