4.0 Article

Detection of the procoagulant activity of microparticle-associated phosphatidylserine using XACT

Journal

BLOOD COAGULATION & FIBRINOLYSIS
Volume 20, Issue 7, Pages 558-564

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MBC.0b013e32832ee915

Keywords

microparticles; phospholipids; thrombin; Xa clotting time

Categories

Ask authors/readers for more resources

One of the mechanisms by which platelet-derived microparticles elicit procoagulant activity is by an increased exposure of phosphatidylserine on their surface. We have previously demonstrated the utility of an activated factor X-based assay for the detection of procoagulant phospholipid activity [Xa clotting time (XACT)]. The objective of this study was to further characterize the specificity of the XACT to detect microparticle-associated procoagulant phospholipid activity. XACT testing for procoagulant phospholipid was measured using an ST4 machine and microparticle counting was performed using flow cytometry for Annexin V binding. Plasma microparticle counts were significantly correlated to XACT times (P=0.0001). The XACT assay was insensitive to tissue factor, whereas the addition of microparticles to a whole blood sample shortened XACT times. Procoagulant phospholipid activity could be detected in both citrate and EDTA anticoagulated samples; however, XACT times and microparticle counts were more stable in EDTA anticoagulated samples over a 60 min period. The procoagulant phospholipid activity of microparticles generated by collagen stimulation was significantly impaired in EDTA anticoagulated samples when compared with citrate. Microparticles were capable of higher degrees of thrombin generation than equivalent concentrations of phosphatidylserine (as assessed by XACT times), suggesting that other factors bound to the microparticle surface enhance the procoagulant response. In conclusion, the XACT assay is a specific method for the detection of procoagulant phospholipid activity arising from phosphatidylserine on the microparticle surface; however, other factors presumably bound to the surface of the microparticle may also contribute to enhanced thrombin generation detectable by prothrombinase assays. Blood Coagul Fibrinolysis 20:558-564 (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available