4.6 Article

Determination of phthalate esters in environmental water by magnetic Zeolitic Imidazolate Framework-8 solid-phase extraction coupled with high-performance liquid chromatography

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1409, Issue -, Pages 46-52

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2015.07.068

Keywords

Magnetic solid-phase extraction (MSPE); Zeolitic lmidazolate Framework-8 (ZIF-8); High-performance liquid chromatography (HPLC); Phthalate esters (PAEs)

Funding

  1. National Natural Science Foundation of China [21305076, 21205068, 31300292]
  2. Key Program of The Dawn of West China Talent Foundation of CAS
  3. Natural Science Foundation of Shandong Province [ZR20128Q022, B52013SW012]
  4. Foundation of Qufu Normal University [BSQD20110118]

Ask authors/readers for more resources

In this study, the magnetic Zeolitic Imidazolate Framework-8 (ZIF-8) microspheres were successfully synthesized and applied as an effective sorbent for preconcentration of several typical phthalate esters (PAEs) from environmental water samples. Firstly, the solvothermal treatment method was used for preparation of Fe3O4 nanoparticles. Then, mercaptoacetic acid (MAA) was served as the functionalized chemical to modify Fe3O4 nanoparticles. The Fe3O4@ZIF-8 core-shell microspheres were synthesized through coating the MAA-capped Fe3O4 nanoparticles with ZIF-8. By coupling magnetic solid-phase extraction (MSPE) with high-performance liquid chromatography (HPLC), a reliable, sensitive and cost-effective method for simultaneous determination of five main PAEs including dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), and dioctyl phthalate (DOP) was developed. Good linearity was observed in the range of 1.0-100.0 mu g/L. The limits of detection (S/N =3) and limits of quantification (S/N = 10) were in the range of 0.08-0.24 and 0.3-0.8 mu g/L, respectively. The relative standard deviations were less than 5.5% and the accuracies of the method for the PAEs were in the range from 85.6% to 103.6%. Finally, the Fe3O4@ZIF-8 was successfully applied for rapid extraction of trace amounts of PAEs in environmental water samples. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available