4.6 Article

Application of hollow fiber membrane mediated with titanium dioxide nanowire/reduced graphene oxide nanocomposite in preconcentration of clotrimazole and tylosin

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1420, Issue -, Pages 46-53

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.chroma.2015.09.063

Keywords

Hollow fiber membrane; High performance liquid chromatography; Nanocomposite; Veterinary drugs

Funding

  1. University of Zanjan
  2. School of Pharmacy, Zanjan University of Medical Sciences

Ask authors/readers for more resources

In this paper, TiO2 nanowires and TiO2 nanoparticles have been successfully anchored on graphene oxide (GO) nanosheets by a facile one-step hydrothermal method. The synthesized TiO2 NWs/RGO and TiO2 NPs/RGO nanocomposites were characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. After comparatively studying of the as-made nanocomposites, TiO2 NWs/RGO nanocomposite showed the best adsorbing performance and applied as an attractive efficient sorbent reinforced with microporous hollow fiber membrane through the sol-gel technology. In the following, the selected nanocomposite was utilized for simultaneous preconcentration and determination of clotrimazole and tylosin using high performance liquid chromatography (HPLC)-UV detection, respectively. In order to optimize the extraction conditions through affecting parameters (pH, stirring rate, salt addition, extraction time and volume of donor phase), response surface methodology (RSM) was employed as a powerful statistical technique. Under the optimal conditions, the limit of detection (S/N =3) of proposed HFSPME method, was 0.67 mu gL(-1) for clotrimazole and 0.91 mu gL(-1) for tylosin with good linear ranges of 1.7-8000.0 mu gL(-1) and 4.0-6000.0 mu gL(-1). The inter-day and intra-day relative standard deviations (RSD%) at 100 mu gL(-1) concentration level were in the ranges of 2.10-3.58% for clotrimazole and 3.45-7.80% for tylosin (n=5), respectively. The proposed microextraction device was extended for determination of ultra trace amounts of target analytes in milk and urine samples with satisfactory results. (C) 2015 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available