4.8 Article

Integrated microdevice of reverse transcription-polymerase chain reaction with colorimetric immunochromatographic detection for rapid gene expression analysis of influenza A H1N1 virus

Journal

BIOSENSORS & BIOELECTRONICS
Volume 33, Issue 1, Pages 88-94

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2011.12.024

Keywords

Integrated microdevice; Reverse transcription-polymerase chain reaction Immunochromatographic strip; Influenza A H1N1 virus; Portable genetic analyzer

Funding

  1. Ministry for Agriculture, Forestry and Fisheries, Republic of Korea
  2. MKE/KEIT [10035638]
  3. Institute of Planning & Evaluation for Technology in Food, Agriculture, Forestry & Fisheries (iPET), Republic of Korea [IPET109189-3] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. Korea Evaluation Institute of Industrial Technology (KEIT) [10035638] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

An integrated microdevice of a reverse transcription-polymerase chain reaction (RT-PCR) reactor and an immunochromatographic strip was constructed for colorimetric detection of gene expression of influenza A virus subtype H1N1. An RT-PCR cocktail, which included Texas Red-labeled primers, dNTP including biotin-labeled dUTP, and RNA templates of influenza A H1N1 virus, was filled in the PCR chamber through the micropump, and the RT-PCR was performed to amplify the target H1 gene (102 bp). The resultant amplicons bearing biotin moieties and Texas Red haptens were subsequently eluted to the immunochromatographic strip, in which they were first conjugated with the gold nanoparticle labeled anti-hapten antibody in the conjugation pad, and then captured on the streptavidin coated test line through the biotin-streptavidin interaction. By observing a violet color in the test line which was derived from the gold nanoparticle, we confirmed the HI NI target virus. The entire process on the integrated microdevice consisting of a micropump, a 2 mu L PCR chamber, and an immunochromatographic strip was carried out on the portable genetic analyzer within 2.5 h, enabling on-site colorimetric pathogen identification with detection sensitivity of 14.1 pg RNA templates. (C) 2011 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available