4.8 Article

A signal-on electrochemiluminescence aptamer biosensor for the detection of ultratrace thrombin based on junction-probe

Journal

BIOSENSORS & BIOELECTRONICS
Volume 26, Issue 5, Pages 2645-2650

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2010.11.028

Keywords

Aptamer biosensor; ECL aptamer biosensor; Junction-probe; Thrombin; Electrochemiluminescence

Funding

  1. NSFC [40875087]
  2. Ministry of Health P. R China [200902009]
  3. National Basic Research Program of China [2010CB732403]
  4. Fujian Provincial Department of Science and Technology [2009J01023, 2010H6010]
  5. Education Department of Fujian Province [JA10295]
  6. Fujian Health Department [2010126]

Ask authors/readers for more resources

A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the junction-probe strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary Y junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0 x 10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available