4.8 Article

Covalent coupling of organophosphorus hydrolase loaded quantum dots to carbon nanotube/Au nanocomposite for enhanced detection of methyl parathion

Journal

BIOSENSORS & BIOELECTRONICS
Volume 25, Issue 6, Pages 1370-1375

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2009.10.032

Keywords

Multiwalled carbon nanotube; CdTe quantum dots; Methyl parathion degrading enzyme; Methyl parathion; Amplification

Funding

  1. National Natural Science Foundation of China [20705010]
  2. Research Fund for the Doctoral Program of Higher Education of China [20070511015]
  3. LDRD program at Pacific Northwest National Laboratory (PNNL)
  4. DOE [DE-AC05-76L01830]

Ask authors/readers for more resources

An amperometric biosensor for highly selective and sensitive determination of methyl parathion (MP) was developed based on dual-signal amplification: (1) a large amount of introduced enzyme on the electrode surface and (2) synergistic effects of nanoparticles towards enzymatic catalysis. The fabrication process includes (1) electrochemical deposition of gold nanoparticles by a multi-potential step technique at multiwalled carbon nanotube (MWCNT) film pre-cast on a glassy carbon electrode and (2) immobilization of methyl parathion degrading enzyme (MPDE) onto a modified electrode through CdTe quantum dots (CdTe QDs) covalent attachment. The introduced MWCNT and gold nanoparticles significantly increased the surface area and exhibited synergistic effects towards enzymatic catalysis. CdTe QDs are further used as carriers to load a large amount of enzyme. As a result of these two important enhancement factors, the proposed biosensor exhibited extremely sensitive, perfectly selective, and rapid response to methyl parathion in the absence of a mediator. The detection limit was 1.0 ng/mL Moreover, since MPDE hydrolyzes pesticides containing the P-S bond, it showed high selectivity for detecting MP and many interfering compounds, such as carbamate pesticides. Other organophosphorous pesticides and oxygen-containing inorganic ions (SO42-, NO3-) did not interfere with the determination. The proposed MPDE biosensor presents good reproducibility and stability, and the MPDE is not poisoned by organophosphate pesticides. Unlike cholinesterase-based biosensor, the MPDE biosensor can be potentially reused and is suitable for continuous monitoring. (C) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available