4.8 Article

Array-based titanium dioxide biosensors for ratiometric determination of glucose, glutamate and urea

Journal

BIOSENSORS & BIOELECTRONICS
Volume 25, Issue 6, Pages 1439-1446

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2009.10.044

Keywords

Array-based biosensor; Multianalytes; Ratiometric measurement; Titanium dioxide

Funding

  1. National Science Council, Taiwan [NSC 96-2113-M-007-027-MY3]

Ask authors/readers for more resources

A novel optical array-based titanium dioxide (TiO2) biosensor combining with simple vapor deposition method was developed to simultaneously determine multianlaytes including glucose, urea and glutamate in serum samples. Carboxy seminaphthorhodamine-1-dextran (SNARF-1-dextran), serving as a single-molecule fluorescent probe, was co-immobilized with different enzymes including urease, glucose dehydrogenase (GDH), and glutamate dehydrogenase (GLDH) for determination of urea, glucose and glutamate simultaneously. The SNARF-1-dextran was a useful pH sensitive dye and the fluorescence ratio at 585 and 630 nm was used to characterize the change in solution pH. Atomic force microscopic (AFM) and scanning electron microscopy (SEM) images showed that TiO2 is a crack-free stable sol-gel material, which can effectively trap enzymes in the sol-gel-derived matrices prepared by vapor deposition method. The surface morphology of the sol-gel-derived TiO2 films changed significantly after the immobilization of macromolecules and enzymes. The array-based TiO2 biosensors show good analytical performance on the simultaneous determination of multiple samples for multianalytes without obvious cross-interference. The analytical ranges of the three analytes in water samples were between 0.01 and 10 mM and limit of detections (LODs) were in the range 2.4-5.5 mu M. In addition, satisfactory dynamic ranges of 2-3 orders of magnitude with LODs of 3.1-7.8 mu M in serum samples were obtained. These results demonstrate the first report of combining a sol-gel-derived TiO2 array biosensor with SNARF-1-dextran for ratiometric determination of multianalytes simultaneously and provide a viable alternative to current silica technology for the fabrication of array-based optical biosensors. (c) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available