4.8 Article

Fractions composition study of the treatment plant

Journal

BIORESOURCE TECHNOLOGY
Volume 103, Issue 1, Pages 459-465

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.biortech.2011.10.007

Keywords

Sludge; Pyrolysis oil; Catalysis; Fuel

Funding

  1. Companhia Estadual de Aguas e Esgotos (CEDAE)
  2. Conselho Nacional de Pesquisa (CNPq)
  3. Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

Ask authors/readers for more resources

In this work the parameters of Low Temperature Conversion - LTC were applied in a centrifuged sludge from a sewage treatment plant located in Rio de Janeiro, Brazil. Before the conversion, the sludge was dried and analyzed by TGA to observe its behavior with increasing temperature. The chemical composition of the crude pyrolysis oil was analyzed by FTIR, H-1 NMR and GC-MS. The results showed that the oil is a mixture of hydrocarbons, oxygenated and nitrogenated compounds. Using a catalytic treatment it was possible to fractionate the oil where the predominant constituents were hydrocarbons showing that the cracking was effective. An important result was the difference between the calorific value of dry sludge (10 MJ kg(-1)), the pyrolysis oil (36 MJ kg(-1)) and one of the fractions separated by catalytic cracking (40 MJ kg(-1)) when compared with commercial diesel (45 MJ kg(-1)). (C) 2011 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available