3.8 Article

Comparison between rectal and body surface temperature in dogs by the calibrated infrared thermometer

Journal

VETERINARY AND ANIMAL SCIENCE
Volume 9, Issue -, Pages -

Publisher

ELSEVIER
DOI: 10.1016/j.vas.2020.100120

Keywords

Body surface temperature; Dog; Infrared thermometer; Health status; Rectal temperature

Funding

  1. European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant [745396]
  2. Latvian State Education Development Agency [1.1.1.2/VIAA/3/19/455]

Ask authors/readers for more resources

Because dogs tolerate conventional rectal temperature measurements poorly, a calibrated infrared thermometer was tested for assessing canine body surface temperature. Body surface temperature of 204 dogs was estimated on various sites (digit, snout, axilla, eye, gum, inguinal region, and anal verge). Having rectal temperature as the gold standard, temperature difference, Spearman's correlation coefficient, hyperthermia and hypothermia detection sensitivity and specificity, and stress response score was calculated for each measurement site. Although the canine body surface temperature was considerably lower than the rectal temperature, there was a moderate correlation between both temperatures. Spearman's coefficients were 0.60 (p < 0.001) for the inguinal region with a single operator and 0.50 (p < 0.001) for the gum with multiple operators. Measurement site on the gum additionally guaranteed hyperthermia detection sensitivity and specificity up to 90.0% (95% CI: [66.7 100]) and 78.6% (95% CI: [71.6 85.2]), respectively. Measurements with the infrared thermometer provoked a statistically significant lower stress response (mean stress scores between 1.89 and 2.48/5) compared to the contact rectal measurements (stress score of 3.06/5). To conclude, the correct body surface temperature measurement should include a calibrated thermometer, reliable sampling, and the control of external factors such as ambient temperature influence. The transformation of body surface temperature to the recognized rectal temperature interval allows more straightforward data interpretation. The gum temperature exhibited the best clinical potential since the differences to rectal temperatures were below 1 degrees C, and hyperthermia was detected with the sensitivity of up to 90%.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available