4.7 Article

Electron Densities in the Solar Corona Measured Simultaneously in the Extreme Ultraviolet and Infrared

Journal

ASTROPHYSICAL JOURNAL
Volume 906, Issue 2, Pages -

Publisher

IOP PUBLISHING LTD
DOI: 10.3847/1538-4357/abcd91

Keywords

-

Funding

  1. Grant Agency of the Czech Republic [18-09072S]
  2. Czech Academy of Sciences [RVO:67985815]
  3. Science Grant Agency project VEGA (Slovakia) [2/0048/20]
  4. SAS [SAV-18-01]
  5. Charles University, project GA UK [1130218]
  6. Royal Society
  7. STFC funding via the consolidated grants to the atomic astrophysics group (AAG) at DAMTP, University of Cambridge [ST/P000665/1, ST/T000481/1]
  8. National Science Foundation [1852977]
  9. STFC [ST/P000665/1, ST/J00054X/1, ST/T000481/1] Funding Source: UKRI

Ask authors/readers for more resources

Accurate measurements of electron density in the solar corona are critical, and this study compares measurements from extreme-ultraviolet and near-infrared lines, finding good agreement. Background subtraction is shown to have a significant impact on density diagnostics.
Accurate measurements of electron density are critical for determination of the plasma properties in the solar corona. We compare the electron densities diagnosed from Fe xiii lines observed by the Extreme-Ultraviolet Imaging Spectrometer (EIS) onboard the Hinode mission with the near-infrared (NIR) measurements provided by the ground-based Coronal Multichannel Polarimeter (CoMP). To do that, the emissivity-ratio method based on all available observed lines of Fe xiii is used for both EIS and CoMP. The EIS diagnostics is further supplemented by the results from Fe xii lines. We find excellent agreement, within 10%, between the electron densities measured from both extreme-ultraviolet and NIR lines. In the five regions selected for detailed analysis, we obtain electron densities of log(N-e [cm(-3)]) = 8.2-8.6. Where available, the background subtraction has a significant impact on the diagnostics, especially on the NIR lines, where the loop contributes less than a quarter of the intensity measured along the line of sight. For the NIR lines, we find that the line center intensities are not affected by stray light within the instrument, and recommend using these for density diagnostics. The measurements of the Fe xiii NIR lines represent a viable method for density diagnostics using ground-based instrumentation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available