Journal
PHARMACEUTICAL RESEARCH
Volume 17, Issue 2, Pages 183-189Publisher
KLUWER ACADEMIC/PLENUM PUBL
DOI: 10.1023/A:1007517414200
Keywords
poorly soluble drugs; hydrocortisone; dissolution rate; solubility; intestinal fluids; bile salts
Ask authors/readers for more resources
Purpose. To compare solubility and dissolution rate of hydrocortisone in aspirated human intestinal fluids (HIFs) with simulated intestinal fluids (SIFs) and buffer. Methods. Solubility and flux from a rotating disk of hydrocortisone were measured. The bile salt content, pH and osmotic pressure were determined in HIFs. Results. In fasted state the solubility of hydrocortisone was higher in HIFs than in the buffer and SIFs. The flux of hydrocortisone in HIFs was similar to the flux in the buffer but lower than the flux in SIFs at fasted state. Addition of intestinal surfactants in SIFs increased solubility and flux at both fasted and fed state. The increase in solubility was caused by micelle formation in SIFs. The increase in flux may partly be explained by increased solubility. The bile salt content of the HIFs did not correlate with the solubility or the flux but pH in the HIFs seems to have some effect on the components of the HIFs resulting in increased solubility. Conclusions. It is possible to perform comparable dissolution tests in HIFs and SIFs. The lack of correlation between the results in HIFs and the bile salt content may be explained by the relatively low lipofilicity of the model drug.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available