4.3 Article

Pupil-size alterations induced by photodisruption during femtosecond laser-assisted cataract surgery

Journal

JOURNAL OF CATARACT AND REFRACTIVE SURGERY
Volume 41, Issue 2, Pages 278-285

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jcrs.2014.10.027

Keywords

-

Funding

  1. Industrial Strategic Technology Development Program - Ministry of Knowledge Economy, South Korea [10040121]
  2. Korea Evaluation Institute of Industrial Technology (KEIT) [10040121] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

PURPOSE: To measure miosis after femtosecond laser pretreatment of cataract surgery and determine correlative factors. SETTING: Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, and Catholic University of Korea, Seoul, South Korea. DESIGN: Cross-sectional study. METHODS: Images extracted from surgical videos of femtosecond laser pretreatment and phacoemulsification were used to measure the pupil area. Quantitative analysis of pupil constriction was performed by comparing consecutive images obtained at the initiation of each procedure. Potential factors related to pupil constriction were examined, including laser parameters and anatomic measurements. RESULTS: The study enrolled 56 eyes. The mean pupil area decreased by 29.7% during the time it took to shift between procedures (shifting time). The total laser treatment duration was highly correlated with the reduction in the pupil area (r = -0.433, P =.001). The amount of intraoperative miosis was significantly correlated with the duration of lens fragmentation by the femtosecond laser (r = -0.416, P =.001) and of primary incision creation (r = -0.289, P =.031). Pupil constriction was correlated with patient age (r = -0.398, P =.002) and the laser capsulotomy pupil margin distance (r = -0.395, P =.003), but not with suction-on time (r = -0.012, P =.930) or shifting time (r = -0.091, P =.506). CONCLUSIONS: The pupil area decreased significantly after femtosecond laser pretreatment of cataract surgery. Intraoperative miosis was most significantly correlated with laser pretreatment duration and patient age.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available