4.5 Article

An experimental and computational investigation of the post-yield behaviour of trabecular bone during vertebral device subsidence

Journal

BIOMECHANICS AND MODELING IN MECHANOBIOLOGY
Volume 12, Issue 4, Pages 685-703

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s10237-012-0434-3

Keywords

Trabecular bone; Pressure-dependent yielding; Hydrostatic compression; Confined compression; microCT finite element analysis; Vertebral subsidence; Crushable foam

Funding

  1. SFI/HEA Irish Centre for High-End Computing (ICHEC)
  2. College of Engineering and Informatics, National University of Ireland Galway

Ask authors/readers for more resources

Interbody fusion device subsidence has been reported clinically. An enhanced understanding of the mechanical behaviour of the surrounding bone would allow for accurate predictions of vertebral subsidence. The multiaxial inelastic behaviour of trabecular bone is investigated at a microscale and macroscale level. The post-yield behaviour of trabecular bone under hydrostatic and confined compression is investigated using microcomputed tomography-derived microstructural models, elucidating a mechanism of pressure-dependent yielding at the macroscopic level. Specifically, microstructural trabecular simulations predict a distinctive yield point in the apparent stress-strain curve under uniaxial, confined and hydrostatic compression. Such distinctive apparent stress-strain behaviour results from localised stress concentrations and material yielding in the trabecular microstructure. This phenomenon is shown to be independent of the plasticity formulation employed at a trabecular level. The distinctive response can be accurately captured by a continuum model using a crushable foam plasticity formulation in which pressure-dependent yielding occurs. Vertebral device subsidence experiments are also performed, providing measurements of the trabecular plastic zone. It is demonstrated that a pressure-dependent plasticity formulation must be used for continuum level macroscale models of trabecular bone in order to replicate the experimental observations, further supporting the microscale investigations. Using a crushable foam plasticity formulation in the simulation of vertebral subsidence, it is shown that the predicted subsidence force and plastic zone size correspond closely with the experimental measurements. In contrast, the use of von Mises, Drucker-Prager and Hill plasticity formulations for continuum trabecular bone models lead to over prediction of the subsidence force and plastic zone.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available