4.8 Article

The use of hydrogel microparticles to sequester and concentrate bacterial antigens in a urine test for Lyme disease

Journal

BIOMATERIALS
Volume 32, Issue 4, Pages 1157-1166

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.biomaterials.2010.10.004

Keywords

Hydrogel; Microparticle; Affinity; Bacteria; Protein

Funding

  1. George Mason University
  2. Italian Istituto Superiore di Sanita, U.S. Department of Health and Human Services, George Mason University, and the Italian Ministry of Public Health
  3. U.S. Department of Energy [DE-FC52-04NA2545]
  4. NIH, NCI [1R21CA137706-01]

Ask authors/readers for more resources

Hydrogel biomarker capturing microparticles were evaluated as a biomaterial to amplify the sensitivity of urine testing for infectious disease proteins. Lyme disease is a bacterial infection transmitted by ticks. Early diagnosis and prompt treatment of Lyme disease reduces complications including arthritis and cardiac involvement. While a urine test is highly desirable for Lyme disease screening, this has been difficult to accomplish because the antigen is present at extremely low concentrations, below the detection limit of clinical immunoassays. N-isopropylacrylamide (NIPAm) - acrylic acid (AAc) microparticles were covalently functionalized with amine containing dyes via arnidation of carboxylic groups present in the microparticles. The dyes act as affinity baits towards protein analytes in solution. NIPAm/AAc microparticles functionalized with acid black 48 (AB48) mixed with human urine, achieved close to one hundred percent capture and 100 percent extraction yield of the target antigen. In urine, microparticles sequestered and concentrated Lyme disease antigens 100 fold, compared to the absence of microparticles, achieving an immunoassay detection sensitivity of 700 pg/mL in 10 mL urine. Antigen present in a single infected tick could be readily detected following microparticle sequestration. Hydrogel microparticles functionalized with high affinity baits can dramatically increase the sensitivity of urinary antigen tests for infectious diseases such as Lyme disease. These findings justify controlled clinical studies evaluating the sensitivity and precision of Lyme antigen testing in urine. (c) 2010 Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available