4.3 Article

Cross contamination in dual inlet isotope ratio mass spectrometers

Journal

INTERNATIONAL JOURNAL OF MASS SPECTROMETRY
Volume 198, Issue 1-2, Pages 45-61

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/S1387-3806(99)00266-3

Keywords

gas isotope ratio mass spectrometry; stable isotopes; cross contamination; normalization; isotopic reference materials

Ask authors/readers for more resources

Since the early days of geochemical isotope ratio mass spectrometry there has always been the problem of cross contamination, i.e. the contamination of the sample gas with traces of reference gas land vice versa) in a dual inlet system and the analyzer itself. This was attributable to valve leakages and could be corrected for. In modem leak-free machines this problem still influences the measurements by scale contraction. It limits the interlaboratory comparability to values unacceptable for, e.g. global carbon cycle investigations on atmospheric delta(13)CO(2), with the need to integrate global datasets at a 0.01 parts per thousand precision level. No matter what the reason of apparent cross contamination (physical leakage, low pump efficiency, gas-wall interactions), we present a method to measure the actual cross contamination as well as algorithms to correct for it. By using isotopically enriched sample gas the effect on the reference gas is directly shown. Especially for biomedical applications, employing highly enriched materials, the nonlinear correction has to be applied. A long-time record of two machines shows the influence of vacuum breakage and the inlet system setup. We present a survey of cross contamination in some of the frequently used machines. The relatively poor raw results of two recent interlaboratory comparison experiments are explained in terms of cross contamination. Whereas the linear two-point normalization procedure considered by itself may be appropriate for some routine applications at natural isotope abundances, it always relies on relative delta values of two reference materials. There is an urgent need to establish absolute values for all scale-determining reference materials. We recommend the use of cross contamination measurements to at least determine the isotopic composition of all normalization materials as long as absolute measurements are not available. In principle, the cross contamination measurements should be used as a diagnostic tool on a regular basis. (C) 2000 Elsevier Science B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available