4.3 Article

VIP-man: An image-based whole-body adult male model constructed from color photographs of the visible human project for multi-particle Monte Carlo calculations

Journal

HEALTH PHYSICS
Volume 78, Issue 5, Pages 476-486

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00004032-200005000-00003

Keywords

Monte Carlo; modeling, dose assessment; imaging; dose, internal

Ask authors/readers for more resources

Human anatomical models have been indispensable to radiation protection dosimetry using Monte Carlo calculations, Existing MIRD-based mathematical models are easy to compute and standardize, but they are simplified and crude compared to human anatomy. This article describes the development of an image-based whole-body model, called VIP-Man, using transversal color photographic images obtained from the National Library of Medicine's Visible Human Project for Monte Carlo organ dose calculations involving photons, electron, neutrons, and protons. As the first of a series of papers on dose calculations based on VIP-Man, this article provides detailed information about how to construct an image-based model, as well as how to adopt it into well-tested Monte Carlo codes, EGS4, MCNP4B, and MCNPX.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available