4.7 Article

Reliability of veterinary drug residue confirmation: High resolution mass spectrometry versus tandem mass spectrometry

Journal

ANALYTICA CHIMICA ACTA
Volume 856, Issue -, Pages 54-67

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2014.11.034

Keywords

High Resolution mass spectrometry; Residue; Confirmation; Commission Decision 93/256/EC; Food safety

Ask authors/readers for more resources

Confirmation of suspected residues has been a long time domain of tandem triple quadrupole mass spectrometry (QqQ). The currently most widely used confirmation strategy relies on the use of two selected reaction monitoring signals (SRM). The details of this confirmation procedure are described in detail in the Commission Decision 93/256/EC (CD). On the other hand, high resolution mass spectrometry (HRMS) is nowadays increasingly used for trace analysis. Yet its utility for confirmatory purposes has not been well explored and utilized, since established confirmation strategies like the CD do not yet include rules for modern HRMS technologies. It is the focus of this paper to evaluate the likelihood of false positive and false negative confirmation results, when using a variety of HRMS based measurement modes as compared to conventional QqQ mass spectrometry. The experimental strategy relies on the chromatographic separation of a complex blank sample (bovine liver extract) and the subsequent monitoring of a number of dummy transitions respectively dummy accurate masses. The term dummy refers to precursor and derived product ions (based on a realistic neutral loss) whose elemental compositions (CxHyNzOdCle) were produced by a random number generator. Monitoring a large number of such hypothetical SRM's, or accurate masses inevitably produces a number of mass traces containing chromatographic peaks (false detects) which are caused by eluting matrix compounds. The number and intensity of these peaks were recorded and standardized to permit a comparison among the two employed MS technologies. QqQ performance (compounds which happen to produce a response in two SRM traces at identical retention time) was compared with a number of different HRMS1 and HRMS2 detection based modes. A HRMS confirmation criterion based on two full scans (an unfragmented and an all ion fragmented) was proposed. Compared to the CD criteria, a significantly lower probability of false positive and false negative findings is obtained by utilizing this criterion. (C) 2014 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available