4.6 Article

Ozone production in the New York City urban plume

Journal

JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES
Volume 105, Issue D11, Pages 14495-14511

Publisher

AMER GEOPHYSICAL UNION
DOI: 10.1029/2000JD900011

Keywords

-

Ask authors/readers for more resources

In the summer of 1996 the Department of Energy G-1 aircraft was deployed in the New York City metropolitan area as part of the North American Research Strategy for Tropospheric Ozone-Northeast effort to determine the causes of elevated O-3 levels in the northeastern United States. Measurements of O-3, O-3 precursors, and other photochemically active trace gases were made upwind and downwind of New York City with the objective of characterizing the O-3 formation process and its dependence on ambient levels of NOx and volatile organic compounds (VOCs). Four flights are discussed in detail. On two of these flights, winds were from the W-SW, which is the typical direction for an O-3 episode. On the other two flights, winds were from the NW, which puts a cleaner area upwind of the city. The data presented include plume and background values of O-3, CO, NOx, and NOy concentration and VOC reactivity. On the W-SW flow days 0, reached 110 ppb. According to surface observations the G-1 intercepted the plume close to the region where maximum 0, occurred. At this point the ratio NOx/NOy was 20-30%, indicating an aged plume. Plume values of CO/NOy agree to within 20% with emission estimates from the core of the New York City metropolitan area. Steady state photochemical calculations were performed using observed or estimated trace gas concentrations as constraints. According to these calculations the local rate of 0, production P(O-3) in all four plumes is VOC sensitive, sometimes strongly so. The local sensitivity calculations show that a specified fractional decrease in VOC concentration yields a similar magnitude fractional decrease in P(O-3). Imposing a decrease in NOx, however, causes P(O-3) to increase. The question of primary interest from a regulatory point of view is the sensitivity of O-3 concentration to changes in emissions of NOx and VOCs. A qualitative argument is given that suggests that the total O-3 formed in the plume, which depends on the entire time evolution of the plume, is also VOC sensitive. Indicator ratios O-3/NOz and H2O2/NOz mainly support the conclusion that plume O-3 is VOC sensitive.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available