Clinical cerebral microdialysis: a methodological study

Journal

JOURNAL OF NEUROSURGERY
Volume 93, Issue 1, Pages 37-43

Publisher

AMER ASSOC NEUROLOGICAL SURGEONS
DOI: 10.3171/jns.2000.93.1.0037

Keywords

microdialysis; cerebral metabolism; clinical examination

Funding

  1. Medical Research Council [G9439390] Funding Source: Medline
  2. Medical Research Council [G9439390] Funding Source: researchfish
  3. MRC [G9439390] Funding Source: UKRI

Ask authors/readers for more resources

Object. Clinical microdialysis enables monitoring of the cerebral extracellular chemistry of neurosurgical patients. Introduction of the technique into different hospitals' neurosurgical units has resulted in variations in the method of application. There are several variables to be considered, including length of the catheter membrane, type of perfusion fluid, flow rate of perfusion fluid, and on-line compared with delayed analysis of samples. The objects of this study were as follows: 1) to determine the effects of varying catheter characteristics on substance concentration; 2) to determine the relative recovery and true extracellular concentration by varying the flow rate and extrapolating to zero flow; and 3) to compare substance concentration obtained using a bedside enzyme analyzer with that of off-line high-performance liquid chromatography (HPLC). Methods. A specially designed bolt was used to conduct two adjacent microdialysis catheters into the frontal cortex of patients with head injury or poor-grade subarachnoid hemorrhage who were receiving ventilation. One reference catheter (10-mm membrane, perfused with Ringer's solution at 0.3 mu l/minute) was constant for all studies. The other catheter was varied in terms of membrane length (10 mm or 30 mm), perfusion fluid (Ringer's solution or normal saline), and flow rate (0.1-1.5 mu l/minute). The effect of freezing the samples on substance concentration was established by on-line analysis and then repeated analysis after storage at - 70 degrees C for 3 months. Samples assayed with the bedside enzyme analyzer were reassessed using HPLC for the determination of glutamate concentrations. Conclusions. Two adjacent microdialysis catheters that were identical in membrane length, perfusion fluid, and flow rate showed equivalent results. Variations in perfusion fluid and freezing and thawing of samples did not result in differences in substance concentration. Catheter length had a significant impact: on substance recovery. Variations in flow rate enabled the relative recovery to be calculated using a modification of the extrapolation-to-zero-flow method. The recovery was approximately 70% at 0.3 mu l/minute and 30% at 1 mu l/minute (10-mm membrane) for all analytes. Glutamate results obtained with the enzyme analyzer showed good correlation with those from HPLC.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available