4.5 Article

Amberlite IR-120 Modified with 8-Hydroxyquinoline as Efficient Adsorbent for Solid-Phase Extraction and Flame Atomic Absorption Determination of Trace Amounts of Some Metal Ions

Journal

BIOLOGICAL TRACE ELEMENT RESEARCH
Volume 145, Issue 2, Pages 240-247

Publisher

HUMANA PRESS INC
DOI: 10.1007/s12011-011-9171-1

Keywords

Solid-phase extraction; Functionalization; 8-Hydroxyquinoline; Amberlite; Preconcentration

Ask authors/readers for more resources

In this study, a solid-phase extraction method combined with atomic absorption spectrometry for extraction, preconcentration, and determination of iron (Fe3+), copper (Cu2+), and lead (Pb2+) ions at trace levels in water samples has been reported. The influences of effective parameters such as flow rate, pH, eluent conditions (type, volume, and concentration), sample volumes, and interference of matrix ions on metal ions recoveries were studied. Under optimized conditions, the limits of detection were found in the range of 0.7-2.2 mu g L-1, while preconcentration factors for Fe3+, Cu2+, and Pb2+ ions were found to be 166, 200, and 250, respectively, and loading half time (t (1/2)) values were less than 2 min for all analyte ions. The proposed procedure was applied for the determination of metal ions in different water samples with recovery of > 94.4% and relative standard deviation less than 4.4% for N = 5.