4.6 Article

Discrimination of sepsis and systemic inflammatory response syndrome by determination of circulating plasma concentrations of procalcitonin, protein complement 3a, and interleukin-6

Journal

CRITICAL CARE MEDICINE
Volume 28, Issue 8, Pages 2793-2798

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00003246-200008000-00019

Keywords

sepsis; systemic inflammatory response syndrome; complement proteins; complement 3a; procalcitonin; interleukin-6; elastase; C-reactive protein

Ask authors/readers for more resources

Objective: To evaluate whether plasma concentrations of procalcitonin (PCT), interleukin-6 (IL-6), protein complement 3a (C3a), leukocyte elastase (elastase), and the C-reactive protein (CRP) determined directly after the clinical onset of sepsis or systemic inflammatory response syndrome (SIRS) discriminate between patients suffering from sepsis or SIBS and predict the outcome of these patients. Design: Prospective study. Setting. Medical intensive care unit at a university hospital. Patients: Twenty-two patients with sepsis and 11 patients with SIRS. Measurements and Main Results: The plasma concentrations of PCT, C3a, and IL-6 obtained less than or equal to 8 hrs after clinical onset of sepsis or SIRS but not those of elastase or CRP were significantly higher in septic patients (PCT: median, 16.8 ng/mL, range, 0.9-351.2 ng/mL, p = .003; C3a: median, 807 ng/mL, range, 422-4788 ng/mL, p < .001; IL-6: median, 382 pg/mL, range, 5-1004 pg/mL, p = .009, all Mann-Whitney rank sum test) compared with patients suffering from SIBS (PCT: median, 3.0 ng/mL, range, 0.7-29.5 ng/mL; C3a: median, 409 ng/mL, range, 279-566 ng/mL; IL-6: median, 98 pg/mL, range, 23-586 pg/mL). The power of PCT, C3a, and IL-6 to discriminate between septic and SIRS patients was determined in a receiver operating characteristic analysis. C3a was the best variable to differentiate between both populations with a maximal sensitivity of 86% and a specificity of 80%. An even better discrimination (i.e., a maximal sensitivity of 91% and a specificity of 80%) was achieved when PCT and C3a were combined in a sepsis score. C3a concentrations also helped to predict the outcome of patients. Based on the sepsis score, a logistic regression model was developed that allows a convenient and reliable determination of the probability of an individual patient to suffer from sepsis or SIRS. Conclusions:Our data show that the determination of PCT, IL-6, and C3a is more reliable to differentiate between septic and SIRS patients than the variables CRP and elastase, routinely used at the intensive care unit. The determination of PCT and C3a plasma concentrations appears to be helpful for an early assessment of septic and SIRS patients in intensive care. (Crit Care Med 2000; 28:2793-2798).

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available