4.7 Article

Determination of trace metal ions by AAS in natural water samples after preconcentration of pyrocatechol violet complexes on an activated carbon column

Journal

TALANTA
Volume 52, Issue 6, Pages 1041-1046

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/S0039-9140(00)00468-9

Keywords

preconcentration; activated carbon column; trace metal; natural waters; AAS

Ask authors/readers for more resources

A simple preconcentration method is described for the determination of Cu, Mn, Co, Cd, Pb, Ni and Cr in water samples by flame AAS. Trace metal ions in water were sorbed as pyrocatechol violet complexes on activated carbon column at the pH range of 4-8, then eluted with 1 M HNO3 in acetone. The effect of major cations and anions of the natural water samples on the sorption of metal ions has been also investigated. The concentration of the metal ions detected after preconcentration was in agreement with the added amount. The present method was found to be applicable to the preconcentration of Cu, Mn, Co, Cd, Pb, Ni and Cr in natural water samples with good results such as R.S.D. from 3 to 8% (N = 10) and detection limits under 70 ng. 1(-1). (C) 2000 Elsevier Science B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available