Multielement analysis of polyethylene using solid sampling electrothermal vaporization ICP mass spectrometry

Journal

ANALYTICAL CHEMISTRY
Volume 72, Issue 18, Pages 4310-4316

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/ac0002700

Keywords

-

Ask authors/readers for more resources

Next to laser ablation (LA) also electrothermal vaporization (ETV) from a graphite furnace as a means of sample introduction opens possibilities for direct analysis of solid samples using inductively coupled plasma mass spectrometry (ICPMS). In this paper, it is demonstrated that solid sampling ETV-ICPMS is very web suited for the determination of metal traces in polyethylene. A limited multielement capability is often cited as an important drawback of ETV-ICPMS. However, by studying the effect of monitoring an increasing number of mass-to-charge ratios on the signal profile (integrated signal intensity and repeatability) of selected analyte elements, the multielement capability of (solid sampling) ETV-ICPMS was systematically evaluated, and the results obtained suggest that,with a quadrupole-based ICPMS instrument, at least 11 elements can be determined simultaneously (from the same vaporization step), in essence without compromising the sensitivity or the precision of the results obtained. In this work, the simultaneous determination of Al, Ba, Cd, Cu, Mn, Pb, and Ti in a polyethylene candidate reference material. has been accomplished, despite the large variation in analyte concentration (from 5 ng/g for Mn to 500 mu g/g for Ti) and in furnace behavior (volatility) they exhibit. To avoid premature losses of Cd during thermal pretreatment of the samples, Pd was used as a chemical modifier. Two different calibration methods external calibration using an aqueous standard solution and single standard additon-were studied and the results obtained were compared with those obtained using neutron activation analysis (NAA) and/or with the corresponding (candidate) certified values (if available). Single standard addition was shown to be preferable (average deviation between ICPMS result and reference value < 3%), although-except for Ba-acceptable results could also be obtained with external calibration.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available