3.8 Article

Slurry chemical corrosion and galvanic corrosion during copper chemical mechanical polishing

Publisher

JAPAN SOC APPLIED PHYSICS
DOI: 10.1143/JJAP.39.6216

Keywords

ultralarge-scale integration (ULSI); copper metallization; damascene; chemical mechanical polishing (CMP); benzotriazole (BTA); barrier metal; galvanic corrosion

Ask authors/readers for more resources

Copper:(Cu) corrosion during chemical mechanical polishing (CMP) was controlled in order to improve the Cu damascene interconnect process. Slurry chemical corrosion was found to be enhanced when the slurry was diluted by deionized (DI) water during rinsing just after CMP. Since the corrosion inhibitor, benzotriazole (BTA), reduces the Cu removal rate, adding it to the rinse solution prevents chemical corrosion more effectively than adding it to the slurry. On the other hand, galvanic corrosion occurs at the interface between Cu and the barrier metal, and it can be prevented by selecting appropriate barrier metals. Because the difference between the electrochemical potentials of Cu and the barrier metal is small in the slurry, refractory metals such as Ta, TaN, and TiN were found to be appropriate barrier metals. On the other hand, W, WN, and Ti have large potential differences, so galvanic corrosion was clearly observed when Cu/W damascene interconnects were fabricated.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available