Time-of night secondary ion mass spectrometry (TOF-SIMS) was used for the analysis of multilayer drug beads that serve as controlled-release drug delivery systems. TOF-SIMS analysis of a cross section of each bead system allowed molecular chemical information to be gained from all of the layers simultaneously, in situ, The integrity of each of the layers was evaluated through imaging of specific ion species for the drug, excipient, and coating materials. The three beads in this study each showed a unique distribution of ingredients. Images of the parent molecular ion for each drug (theophylline, paracetamol, prednisolone) showed their distribution ranged from micrometer-sized particles in one bead cross section to almost homogeneous in another bead cross section. The chemical composition of each of the layers in the beads was evaluated through mass spectrometry; the ingredients did not always match the manufacturer's specification. In addition, many common drug head ingredients were analyzed as pure substances, providing TOF-SIMS reference spectra of these materials for the first time.