4.6 Article Proceedings Paper

Optimization of the spectral data processing in a LIBS simultaneous elemental analysis system

Journal

SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY
Volume 56, Issue 6, Pages 725-736

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0584-8547(01)00186-0

Keywords

LIBS; data processing; mineral ores; coal; deconvolution

Categories

Ask authors/readers for more resources

An instrumentation variation on laser-induced breakdown spectroscopy (LIBS) is described that allows simultaneous determination of all detectable elements using a multiple spectrograph and synchronized, multiple CCD spectral acquisition system. The system is particularly suited to the rapid analysis of heterogeneous materials such as coal and mineral ores. For the analysis of a heterogeneous material the acquisition cycle typically stores 1000 spectra for subsequent filtering and analysis. The incorporation of an effective data analysis methodology has been critical in achieving both accurate and reproducible results in the analysis of powders with the technology. Using naturally occurring gypsum as the optimization matrix, various data analysis techniques have been investigated including: using pulse-to-pulse internal standardization; data filtering; and spectral deconvolution. The incorporation of normalization of the elemental emission to the total plasma emission intensity has been found to yield the single biggest improvement in accuracy and precision. Spectral deconvolution has been found to yield further improvement and is particularly relevant to the analysis of complex materials such as black coal. The use of pulse-to-pulse intensity normalization has the further benefit of extending the period between instrument recalibration, thus enhancing the ease of use of the device. The benefit of the optimized data analysis methodology is revealed in the determination of eight elemental components of gypsum (Na, Ca, Mg, Fe, Al, Si, Ti and K) where a typical absolute analysis accuracy of +/- 10% is obtained. These results compare favourably to analysis by conventional techniques for these materials. The analysis accuracy and repeatability is further demonstrated by the determination of the concentrations of these elements in a black coal sample. (C) 2001 Elsevier Science B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available