4.5 Article

Allergen-induced basophil activation:: CD63 cell expression detected by flow cytometry in patients allergic to Dermatophagoides pteronyssinus and Lolium perenne

Journal

CLINICAL AND EXPERIMENTAL ALLERGY
Volume 31, Issue 7, Pages 1007-1013

Publisher

WILEY
DOI: 10.1046/j.1365-2222.2001.01122.x

Keywords

basophil activation test; CD63; inhalant allergens; in vitro allergologic diagnosis

Ask authors/readers for more resources

Background In this study, we determined by flow cytometry the percentage of basophils activated after in vitro stimulation by allergens and expressing the CD63 marker. The diagnostic reliability of the technique was assessed as well as its correlation with other in vitro diagnostic parameters. Methods Fifty-three patients suffering from asthma and/or allergic rhinitis following sensitization to Dermatophagoides pteronyssinus and 51 patients sensitized to Lolium perenne were investigated. Twenty-four atopic patients not sensitive to these allergens and 38 healthy subjects were also selected as controls. The basophil activation test determines the percentage of basophils which express CD63 as an activation marker, by means of flow cytometry, after in vitro stimulation with allergen, using double labelling with monoclonal antibody anti-CD63-PE and anti-IgE-FITC. Results No differences in basal values (non-activated control) were found between sensitized patients, atopic controls and healthy controls. On the other hand, sensitized patients showed a significantly higher percentage of activated basophils after stimulation by allergens in vitro than both control groups (P<0.001). We found a significant correlation between skin tests and basophil activation tests (r=0.72, P<0.001). We also found a positive and significant correlation between basophil activation tests and histamine release tests (r=0.80, P<0.001), allergen-specific sulphidoleukotriene production (r=0.7, P<0.001) and the occurrence of serum allergen-specific IgE (r=0.71, P<0.001). Conclusion The basophil activation test is a highly reliable technique in the diagnosis of allergy to inhalant allergens. The sensitivity of the basophil activation test was 93.3%, and its specificity 98.4%, when using a cut-off point of 15% activated basophils as positive result.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available