4.7 Review

Patent foramen ovale: A review of associated conditions and the impact of physiological size

Journal

JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY
Volume 38, Issue 3, Pages 613-623

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/S0735-1097(01)01427-9

Keywords

-

Ask authors/readers for more resources

Patent foramen ovale (PFO) is implicated in platypnea-orthodeoxia, stroke and decompression sickness (DCS) in divers and astronauts. However, PFO size in relation to clinical illness is largely unknown since few studies evaluate PFO, either functionally or anatomically. The autopsy incidence of PFO is approximately 27% and 6% for a large defect (0.6 cm to 1.0 cm). A PFO is often associated with atrial septal aneurysm and Chiari network, although these anatomic variations are uncommon. Methodologies for diagnosis and anatomic and functional sizing of a PFO include transthoracic echocardiography (TTE), transesophageal echocardiography (TEE) and transcranial Doppler (TCD), with saline contrast. Saline injection via the right femoral vein appears to have a higher diagnostic yield for PFO than via the right antecubital vein. Saline contrast with TTE using native tissue harmonics or transmitral pulsed wave Doppler have quantitated PFO functional size, while TEE is presently the reference standard. The platypnea-orthodeoxia syndrome is associated with a large resting PFO shunt. Transthoracic echocardiography, TEE and TCD have been used in an attempt to quantitate PFO in patients with cryptogenic stroke. The larger PFOs (approximately greater than or equal to4 mm size) or those with significant resting shunts appear to be clinically significant. Approximately two-thirds of divers with unexplained DCS have a PFO that may be responsible and may be related to PFO size. Limited data are available on the incidence of PFO in high altitude aviators with DCS, but there appears to be a relationship. A large decompression stress is associated with extra vehicular activity (EVA) from spacecraft. After four cases of serious DCS in EVA simulations, a resting PFO was detected by contrast TTE in three cases. Patent foramen ovales vary in both anatomical and functional size, and the clinical impact of a particular PFO in various situations (platypnea-orthodeoxia, thromboembolism, DCS in underwater divers, DCS in high-altitude aviators and astronauts) may be different. (C) 2001 by the American College of Cardiology.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available