4.3 Article

Performance improvement of a pulse tube cooler below 4 K by use of GdAlO3 regenerator material

Journal

CRYOGENICS
Volume 41, Issue 9, Pages 693-696

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/S0011-2275(01)00146-1

Keywords

pulse tuber; regenerators; heat capacity; liquid helium

Ask authors/readers for more resources

The cooling power and coefficient of performance of a two-stage pulse tube cooler below 4 K have been increased greatly by using the newly developed ceramic magnetic regenerative material GdAlO3 (GAP). Cooling powers of 200 mW at 2.8 K, 300 mW at 3.13 K, and 400 mW at 3.70 K have been achieved with a compressor input power of about 4.8 kW. The results show that the cooling power near 3.0 K increases by 150% compared to that of the same pulse tube cooler (PTC) employing only conventional HoCu2, and ErNi regenerator materials. (C) 2001 Elsevier Science Ltd. All rights reserved.