4.6 Article

Parametric dependence of SAR on permittivity values in a man model

Journal

IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING
Volume 48, Issue 10, Pages 1169-1177

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/10.951520

Keywords

dielectric values; dosimetry; electromagnetic fields (EMFs); finite-difference time-domain (FDTD); radio frequency

Ask authors/readers for more resources

The development and widespread use of advanced three-dimensional digital anatomical models to calculate specific absorption rate (SAR) values in biological material has resulted in the need to understand how model parameters (e.g., permittivity value) affect the predicted whole-body and localized SAR values. The application of the man dosimetry model requires that permittivity values (dielectric value and conductivity) be allocated to the various tissues at all the frequencies to which the model will be exposed. In the 3-mm-resolution man model, the permittivity values for all 39 tissue-types were altered simultaneously for each orientation and applied frequency. In addition, permittivity values for muscle, fat, skin, and bone marrow were manipulated independently. The finite-difference time-domain code was used to predict localized and whole-body normalized SAR values. The model was processed in the far-field conditions at the resonant frequency (70 MHz) and above (200,400,918, and 2060 MHz) for E orientation. In addition, other orientations (K, H) of the model to the incident fields were used where no substantial resonant frequency exists. Variability in permittivity values did not substantially influence whole-body SAR values, while localized SAR values for individual tissues were substantially affected by these changes. Changes in permittivity had greatest effect on localized SAR values when they were low compare to the whole-body SAR value or when errors involved tissues that represent a substantial proportion of the body mass (i.e., muscle). Furthermore, we establish the partial derivative of whole-body and localized SAR values with respect to the dielectric value and conductivity for muscle independently. It was shown that uncertainties in dielectric value or conductivity do not substantially influence normalized whole-body SAR. Detailed investigation on localized SAR ratios showed that conductivity presents a more substantial factor in absorption of energy in tissues than dielectric value for almost all applied exposure conditions.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available