4.6 Article

Micro-flow-injection analysis (μFIA) immunoassay of herbicide residue 2,6-dichlorobenzamide - towards automated at-line monitoring using modular microfluidics

Journal

ANALYST
Volume 140, Issue 5, Pages 1616-1623

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c4an01576b

Keywords

-

Funding

  1. Danish Agency for Science, Technology and Innovation [2104-06-000]
  2. Danish Council for Strategic Research [1308-00027B]
  3. Maelkeafgiftsfonden
  4. joint KAIST-DTU signature project, INTEGRATED WATER TECHNOLOGY

Ask authors/readers for more resources

As a part of developing new systems for continuously monitoring the presence of pesticides in ground-water, a microfluidic amperometric immunosensor was developed for detecting the herbicide residue 2,6-dichlorobenzamide (BAM) in water. A competitive immunosorbent assay served as the sensing mechanism and amperometry was applied for detection. Both the immunoreaction chip (IRC) and detection (D) unit are integrated on a modular microfluidic platform with in-built micro-flow-injection analysis (mu FIA) function. The immunosorbent, immobilized in the channel of the IRC, was found to have high long-term stability and withstand many regeneration cycles, both of which are key requirements for systems utilized in continuous monitoring. The IRC was regenerated during 51 cycles in a heterogeneous competitive assay out of which 27 were without the analyte (the highest possible signal level) in order to assess the regeneration capability of the immunosorbent. Detection of BAM standard solutions was performed in the concentration range from 62.5 mu g L-1 to 0.0008 mu g L-1. Non-linear regression of the data using the four-parameter logistic equation generated a sigmoidal standard curve showing an IC50 value (concentration that reduces the signal by 50%) of 0.25 mu g L-1. The strongest signal variation is observed in the concentration range between 0.02 and 2.5 mu g L-1, which includes the 0.1 mu g L-1 threshold limit set by the European Commission for BAM in drinking water. The presented results demonstrate the potential of the constructed mu FIA immunosensor as an at-line monitoring system for controlling the quality of ground water supply.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available