4.5 Article

Numerical evaluation of alternate tube configurations for particle deposition rate reduction in heat exchanger tube bundles

Journal

INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW
Volume 22, Issue 5, Pages 525-536

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/S0142-727X(01)00110-2

Keywords

tube bundles; heat exchangers; numerical simulation; vortex shedding; fouling

Ask authors/readers for more resources

The potential of two passive techniques, namely elliptic-shaped tubes and asymmetric tube bundle arrangement, for deposition rate reduction in lignite-fired utility boiler heat exchangers is numerically studied through comparison with an in-line tube arrangement with circular tubes. The simulation is based on a two-dimensional calculation of the turbulent two-phase flow in heat exchanger tube bundles using a subgrid-scale model for the small-scale turbulent structures and a particle adhesion model for the particle-surface interaction. Large-scale motion is found to be an important mechanism for tube surface fouling. Of the three tube bundle arrangements that were studied, the in-line tube bundle with elliptic-shaped tubes shows the lowest fouling rates and pressure drop. Taking advantage of these, heat transfer rates might be increased by placing more rows in the same area. (C) 2001 Elsevier Science Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available