4.7 Article

Investigation of heat pipe cooling in drilling applications. Part 1: preliminary numerical analysis and verification

Journal

Publisher

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/S0890-6955(01)00155-9

Keywords

drilling; heat pipe cooling

Ask authors/readers for more resources

A combined numerical and experimental study is performed to analyze the feasibility of using heat pipe cooling in drilling applications. A parametric study is conducted to analyze the effect of different geometrical parameters expected for a heat pipe drill configuration, such as depth of the heat pipe within the drill, heat pipe diameter, heat flux input magnitude and length of the heat input zone. In this model, it is assumed that the drill is subjected to a static heat source which verifies the analysis and feasibility of using heat pipe cooling in drilling operations. The performance of the heat pipe drill model is approximated using a solid cylinder model of pure conduction. To validate the assumptions, numerical results are compared with experimental data that are based on the solid cylinder model. Both the numerical and experimental studies show that the use of a heat pipe in a drill can reduce the temperature field significantly. The results of this study can be used to define geometrical parameters for 'optimal' design and the setup for further analysis. (C) 2002 Elsevier Science Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available