4.7 Article

Responses of transpiration and photosynthesis to reversible changes in photosynthetic foliage area in western red cedar (Thuja plicata) seedlings

Journal

TREE PHYSIOLOGY
Volume 22, Issue 6, Pages 363-371

Publisher

HERON PUBLISHING
DOI: 10.1093/treephys/22.6.363

Keywords

compensatory responses; photosynthetic rate; stomatal conductance; transpiration rate

Categories

Ask authors/readers for more resources

Experiments were conducted on 1-year-old western red cedar (Thuja plicata Donn.) seedlings to determine the response of illuminated foliage to reversible changes in total photosynthetic foliage area (LA). Reductions in LA were brought about by either shading the lower foliage or by reducing the ambient CO2 concentration (c(a)) of the air surrounding the lower part of the seedling. In the latter case, the vapor pressure was also changed so that transpiration rates (E) could be manipulated independently of photosynthetic rates (A). We hypothesized that following such treatments, short-term compensatory changes would occur in stomatal conductance (g(s)) and A of the remaining foliage. These changes would occur in response to hydraulic signals generated by changes in the water potential gradient rather than changes in the distribution of sources and sinks of carbon within the seedling. When a portion of the foliage was shaded, there was an immediate reduction in whole-seedling E and a concomitant increase in g(s), A and E in the remaining illuminated foliage. However, the intercellular CO2 concentration did not change. These compensatory effects were fully reversed after the shade was removed. When the lower foliage A was reduced to < 0 mumol m(-2) s(-1), by shading or lowering c(a), and E was either unchanged or increased (by adjusting the vapor pressure deficit), there was no significant increase in g(s) and A in the remaining foliage. We conclude that compensatory responses in illuminated foliage occur only when reductions in L-A are accompanied by a reduction in whole-plant E. The relationship between the reduction 2 in whole-seedling E and the increase in A is highly linear (r(2) = 0.68) and confirms our hypothesis of the strong regulation of g(s) by hydraulic signals generated within the seedling. We suggest that the mechanism of the compensatory effects is a combination of both increased CO2 supply, resulting from increased g(s), and a response of the rate of carboxylation, possibly related to the activity of Rubisco.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available