4.7 Article

Evaluation of the VITEK 2 system for identification and antimicrobial susceptibility testing of medically relevant gram-positive cocci

Journal

JOURNAL OF CLINICAL MICROBIOLOGY
Volume 40, Issue 5, Pages 1681-1686

Publisher

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.40.5.1681-1686.2002

Keywords

-

Categories

Ask authors/readers for more resources

A study was conducted to evaluate the new VITEK 2 system (bioMerieux) for identification and antibiotic susceptibility testing of gram-positive cocci. Clinical isolates of Staphylococcus aureus (n = 100), coagulase-negative staphylococci (CNS) (n = 100), Enterococcus spp. in = 89), Streptococcus agalactiae (n = 29), and Streptococcus pneumoniae (n = 66) were examined with the ID-GPC identification card and with the AST-P515 (for staphylococci), AST-P516 (for enterococci and S. agalactiae) and AST-P506 (for pneumococci) susceptibility cards. The identification comparison methods were the API Staph for staphylococci and the API 20 Strep for streptococci and enterococci; for antimicrobial susceptibility testing, the agar dilution method according to the procedure of the National Committee for Clinical Laboratory Standards (NCCLS) was used. The VITEK 2 system correctly identified to the species level (only one choice or after simple supplementary, tests) 99% of S. aureus, 96.5% of S. agalactiae, 96.9% of S. pneumoniae, 92.7% of Enterococcus faecalis, 91.3% of Staphylococcus haemolyticus, and 88% of Staphylococcus epidermidis but was least able to identify Enterococcus faecium (71.4% correct). More than 90% of grain-positive cocci were identified within 3 It. According to the NCCLS breakpoints, antimicrobial susceptibility testing with the VITEK 2 system gave 96% correct category agreement, 0.82% very major errors, 0.17% major errors, and 2.7% minor errors. Antimicrobial susceptibility testing showed category agreement from 94 to 100% for S. aureus, from 90 to 100% for CNS, from 91 to 100% for enterococci, from 96 to 100% for S. agalactiae, and from 91 to 100% for S. pneumoniae. Microorganism-antibiotic combinations that gave very major errors were CNS-erythromycin, CNS-oxacillin, enterococci-teicoplanin, and enterococci-high-concentration gentamicin. Major errors were observed for CNS-oxocillin and S. agalactiae-tetracycline combinations. In conclusion the results of this study indicate that the VITEK 2 system represents an accurate and acceptable means for performing identification and antibiotic susceptibility tests with medically relevant gram-positive cocci.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available