4.4 Article

Evaluation of accelerator mass spectrometry in a human mass balance and pharmacokinetic study-experience with 14C-labeled (R)-6-[amino(4-chlorophenyl)(1-methyl-1H-imidazol-5-yl)methyl]-4-(3-chlorophenyl)-1-methyl-2(1H)-quinolinone (R115777), a farnesyl transferase inhibitor

Journal

DRUG METABOLISM AND DISPOSITION
Volume 30, Issue 7, Pages 823-830

Publisher

AMER SOC PHARMACOLOGY EXPERIMENTAL THERAPEUTICS
DOI: 10.1124/dmd.30.7.823

Keywords

-

Ask authors/readers for more resources

Accelerator mass spectrometry (AMS) has been used in a human mass balance and metabolism study to analyze samples taken from four healthy male adult subjects administered nanoCurie doses of the farnesyl transferase inhibitor C-14-labeled (R)-6-[amino(4-chlorophenyl)(1-methyl-1H-imidazol-5-yl)methyl]-4-(3-chlorophenyl)-1-methyl-2(1H)-quinolinone ([C-14]R115777). Plasma, urine, and feces samples were collected at fixed timepoints after oral administration of 50 mg [C-14]R115777 (25.4 Bq/mg or 687 pCi/mg i.e., equivalent to 76.257 x 10(3) dpm) per subject. AMS analysis showed that drug-related 14 C was present in the plasma samples with C-max values ranging from 1.6055 to 2.9074 dpm/ml (1.0525-1.9047 mug/ml) at t(max) = 2 to 3 h. The C-max values for acetonitrile extracts of plasma samples ranged from 0.3724 to 0.7490 dpm/ml in the four male subjects. Drug-related C-14 was eliminated from the body both in the urine and the feces, with a mean total recovery of 79.8 +/- 12.9% in the feces and 13.7 +/- 6.2% in the urine. The majority of drug-related radioactivity in urine and feces was excreted within the first 48 h. High-performance liquid chromatography (HPLC)-AMS profiles were generated from radioactive parent drug plus metabolites from pooled diluted urine, plasma, and methanolic feces extracts and matched to retention times of synthetic reference substances, postulated as metabolites. All HPLC separations used no more than 5 dpm injected on-column. The radioactive metabolite profiles obtained compared well with those obtained using liquid chromatography/tandem mass spectometry. This study demonstrates the use of AMS in a human phase I study in which the administered radioactive dose was at least 1000-fold lower than that used for conventional radioactive studies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available