4.7 Article

Radial patterns of sap flow in woody stems of dominant and understory species:: scaling errors associated with positioning of sensors

Journal

TREE PHYSIOLOGY
Volume 22, Issue 13, Pages 907-918

Publisher

HERON PUBLISHING
DOI: 10.1093/treephys/22.13.907

Keywords

correction factors; integration; multi-point sensor; Pinus; Populus; potential sapwood; Prunus; random errors; Rhododendron; sapwood; single-point sensor; spatial variation; systematic errors; temporal variation

Categories

Ask authors/readers for more resources

We studied sap flow in dominant coniferous (Pinus sylvestris L.) and broadleaf (Populus canescens L.) species and in understory species (Prunus serotina Ehrh. and Rhododendron ponticum L.) by the heat field deformation (HFD) method. We attempted to identify possible errors arising during flow integration and scaling from single-point measurements to whole trees. Large systematic errors of -90 to 300% were found when it was assumed that sap flow was uniform over the sapwood depth. Therefore, we recommend that the radial sap flow pattern should be determined first using sensors with multiple measuring points along a stem radius followed by single-point measurements with sensors placed at a predeterinined depth. Other significant errors occurred in the scaling procedure even when the sap flow radial pattern was known. These included errors associated with uncertainties in the positioning, of sensors beneath the cambium (up to 15% per I m in error in estimated xylem depth), and differences in environmental conditions when the radial profile applied for integration was determined over the short term (up to 47% error). High temporal variation in the point-to-area correction factor along the xylem radius used for flow integration is also problematic. Compared with midday measurements, measurements of radial variation of sap flow in the morning and evening of sunny days minimized the influence of temporal variations on the point-to-area correction factor, which was especially pronounced in trees with a highly asymmetric sap flow radial pattern because of differences in functioning of the sapwood xylem layers. Positioning a single-point sensor at a depth with maximum sap flow is advantageous because of the high sensitivity of maximum sap flow to water stress conditions and changes in micro-climate, and because of the lower random errors associated with the positioning of a single-point sensor along the xylem radius.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available