4.6 Article Proceedings Paper

Replacing the ascending aorta and aortic valve for acute prosthetic valve endocarditis: Is using prosthetic material contraindicated?

Journal

ANNALS OF THORACIC SURGERY
Volume 74, Issue 5, Pages S1781-S1785

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/S0003-4975(02)04142-5

Keywords

-

Ask authors/readers for more resources

Background. The use of prosthetic material (rather than a homograft) for ascending aorta/aortic valve replacement (Bentall procedure) in cases of acute prosthetic valve endocarditis is controversial. We report favorable results using this technique almost exclusively (a homograft was used in only 3 patients with hernatological problems) during a 12-year interval. Methods. Twenty-eight patients (55 +/- 14 years; 22 male) underwent a Bentall procedure for acute prosthetic valve endocarditis between 1988 and 2000. Twenty-five patients had undergone previous aortic valve replacement (1 with concomitant mitral valve replacement, 4 with coronary artery bypass grafting), and 3 had had a previous Bentall operation. The median interval between initial surgery and reoperation was 13 months (range, 1 to 106). Sixty-eight percent of operations were urgent or emergencies. Ninety-three percent of patients had significant aortic regurgitation; complete annuloaortic dehiscence occurred in 71%, and in 57%, an abscess was found. Causative organisms were identified in 25 of 28 patients: Staphylococcus epidermidis (9), Staphylococcus aureus (7), Streptococcus viridans (6), Pseudomonas (2), and Legionella (1). Results. Twenty-three patients had mechanical and 5 had biological valves implanted during the Bentall procedure. Hypothermic circulatory arrest was used in 64%. Hospital mortality was 11%: there was one intraoperative death, and two before discharge (one cardiac, one sepsis). Eighty-nine percent survived without stroke. During follow-up (median, 44.5 months; complete in 92%), 1 patient died of recurrent endocarditis at 4 months. Conclusions. These results indicate that prosthetic root replacement may be superior to use of a homograft for acute aortic prosthetic valve endocarditis, with only a 4% incidence of recurrent endocarditis and reoperation. (C) 2002 by The Society of Thoracic Surgeons.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available