4.6 Article

Potentiated hepatic microcirculatory response to endothelin-1 during polymicrobial sepsis

Journal

SHOCK
Volume 18, Issue 5, Pages 415-422

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/00024382-200211000-00005

Keywords

liver microcirculation; intravital microscopy; abdominal sepsis; endothelin-1; nitric oxide

Funding

  1. NIDDK NIH HHS [DK 38201] Funding Source: Medline

Ask authors/readers for more resources

We conducted this study to elucidate the role of endothelins (ET-1) in mediating the hepatic microcirculatory dysfunction observed in response to sepsis. Following 24 h of cecal ligation and puncture (CLP), we performed intravital microscopy both in vivo and on isolated perfused livers. Portal resistance increased in response to ET-1 in both sham and septic rats, with no significant difference between the two in either in vivo or in isolated livers. Sinusoidal volumetric flow (Q.) was evaluated using red blood cell velocity (V-RBC) and sinusoidal diameter (D.) to determine microvascular hemodynamic integrity. Q. decreased in response to ET-1 in livers from CLP rats compared with sham (P < 0.05, CLP vs. sham) in both in vivo and isolated livers. In vivo infusion of ET-1 resulted in greater constriction of sinusoids in the CLP group compared with sham (P < 0.05), resulting in higher sinusoidal resistance. Microvascular hyper-responsiveness was accompanied by hepatocellular injury in CLP rats, but not in sham rats. RT-PCR was performed to measure mRNA levels of ET-1, its receptors ETA and ET., inducible and constitutive nitric oxide (NO) synthase (iNOS and eNOS, respectively), and heme oxygenase 1 (HO-1). After CLP, both ET-1 and ETB mRNA increased, whereas ETA mRNA tended to decrease, although the change was not statistically significant. Livers from CLP rats showed no significant change in levels of eNOS mRNA, but showed a significant increase in NOS expression (13.5-fold over sham). There was no change in the level of HO-1 mRNA between sham and CLP groups. Taken together, these results suggest that sepsis sensitizes the hepatic microcirculation to ET-1. More importantly, an impaired microcirculatory flow due to ET-1 in sepsis contributes to hepatic injury. Further, localized imbalances between endothelins and NO may mediate the altered microvascular response during sepsis.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available