4.6 Article

Determination of dithiocarbamate pesticides in occupational hygiene sampling devices using the isooctane method and comparison with an automatic thermal desorption (ATD) method

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 984, Issue 1, Pages 81-88

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/S0021-9673(02)01771-5

Keywords

thermal desorption; air analysis; dithiocarbamates; carbamates; pesticides

Ask authors/readers for more resources

Two new methods for the determination of dithiocarbamate pesticides in occupational hygiene sampling devices are described. Dithiocarbamate spiked occupational hygiene sampling devices, consisting of glass fibre (GF/A) filters, cotton pads, cotton gloves and disposable overalls, were reduced under acidic conditions and the CS, evolved as a decomposition product was extracted into isooctane. The isooctane was then analysed using gas chromatography with mass spectrometry, for CS2, which provided a quantitative result for dithiocarbamates. Recoveries obtained were generally within a 70-110% range and reproducibilities better than 15% RSD were typically achieved. The method has been successfully applied to samples collected during occupational exposure surveys. A second method employing automatic thermal desorption-gas chromatography-mass spectrometry (ATD-GC-MS) has also been developed and applied to the direct analysis of GF/A (airborne) samples. The method relies on the thermal degradation of dithiocarbamates to release CS2, which is used to quantify the analytes. Thiram spiked GF/A filters gave an average recovery of 107% with an RSD of 4%. The performance of the two analytical methods were directly compared by analysing sub-portions of GF/A filters collected during a survey to evaluate occupational exposures to thiram during seed treatment operations. Both methods performed well for the analysis of airborne (GF/A) samples and produced results in good agreement. ATD-GC-MS is the preferred method for studies involving GF/A (airborne) samples only. Because of the wider applicability of the isooctane method for other sampling devices, it is the preferred choice when carrying out surveys which require a dermal as well as respirable exposure assessment. Crown Copyright 2002 Published by Elsevier Science B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available