4.2 Article

Comparison of Column Solid-Phase Extraction Procedures for Spectrophotometric Determination of E129 (Allura Red) in Foodstuff, Pharmaceutical, and Energy Drink Samples

Journal

JOURNAL OF AOAC INTERNATIONAL
Volume 98, Issue 4, Pages 946-952

Publisher

AOAC INT
DOI: 10.5740/jaoacint.14-222

Keywords

-

Funding

  1. Nigde University [FEB2012/23]

Ask authors/readers for more resources

Two novel spectrophotometric determination procedures based on retention of Allura Red onto Amberlite XAD-1180 and XAD-16 resins for its preconcentration, purification, and separation were developed. Analytical parameters of the methods including pH, eluent type, sample volume, and sample and eluent flow rates, were investigated and optimized. Interference effects of some cations, anions, and widely used food dyes were also investigated. Detection limits of the two methods were found to be 1.2 and 1.5 mu g/L for XAD-1180 and XAD-16 columns, respectively, under optimum conditions. Linear calibration curve ranges of the methods were 0.4-8.0 and 0.5-6.0 mu g/mL of Altura Red for XAD-1180 and XAD-16 resins, respectively. Preconcentration factors were found as 80 for both the XAD-1180 and XAD-16 columns using maximum sample volume and minimum eluent volume. RSDs of the methods were below 6% throughout all experiments. All absorbance measurements were performed at 506 nm. Validations of the methods were performed comparatively with determination of the Allura Red contents of some foodstuff, pharmaceutical, and energy drink samples. Allura Red concentrations in investigated solid and liquid samples ranged from 298 to 501 mu g/g and 53.8 to 508 mu g/mL, respectively. Satisfactory results were obtained from the real samples analysis. Allura Red contents of samples were determined to be highly similar using the two extraction methods. Comparisons of the methods were performed by analysis of Allura Red contents of the real samples. In addition to analytical parameters, adsorption isotherm studies were performed for the two kinds of Amberlite resins. It was observed that developed methods fit the linear form of the Freundlich adsorption isotherm model. All of the experimental results suggested that the developed SPE procedures are suitable for separation, preconcentration, and determination of Allura Red in solid and liquid matrixes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available