4.7 Article

Quantification of 8-iso-prostaglandin-F2α and 2,3-dinor-8-isoprostaglandin-F2α in human urine using liquid chromatography-tandem mass spectrometry

Journal

FREE RADICAL BIOLOGY AND MEDICINE
Volume 34, Issue 4, Pages 409-418

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/S0891-5849(02)01018-3

Keywords

free radicals; quantification; 8-iso-prostaglandin F-2 alpha; 2,3-dinor-8-iso-prostaglandin F-2 alpha; LC-MS/MS; human urine; oxidative stress

Ask authors/readers for more resources

Quantification of 8-iso-prostaglandin F-2alpha (8-iso-PGF(2alpha)) has been suggested to be a reliable indicator of lipid peroxidation that may be related to in vivo free radical generation, oxidative damage, and antioxidant deficiency. We have developed a LC-MS/MS method to quantify 8-iso- PGF(2alpha) and its dinor metabolite, 2,3-dinor- 8-iso-prostaglandin F-2alpha (2,3-dinor-8-iso-PGF(2alpha)), in human urine samples. After an initial purification step using an automated C18 solid phase extraction procedure, the urine sample was injected directly into a liquid chromatography (LC) system and detected with tandem mass spectrometry. The detection limit of the assay was 9 pg for, 8-iso-PGF(2alpha) and 3 pg for 2,3-dinor-8-iso-PGF(2alpha) with both inter- and intraday variations of less than 12%. The inaccuracies were less than 3% for both analytes at three different levels. The urinary excretion rate of 2,3-dinor-8-iso-PGF(2alpha) was higher than that of 8-iso-PGF(2alpha), and changed in proportion to the parent compound (R = 0.70, n = 60). Values obtained with this method showed good linear correlation to duplicate 8-iso-PGF(2alpha) measurements performed with GCMS (R = 0.97, n = 15). The mean excretion rates of 8-iso-PGF(2alpha) and 2,3-dinor-8-iso-PGF(2alpha) were significantly higher in smokers than in nonsmokers (0.53 +/- 0.37 vs. 0.25 +/- 0.15 mug/g creatinine, p = 0.002 for 8-iso-PGF(2alpha) and 8.9 +/- 3.8 vs. 4.6 +/- 2.6 mug/g creatinine, p = 0.003 for 2,3-dinor-8-iso-PGF(2alpha), respectively). The excellent accuracy, reproducibility, and high throughput of this method should permit it to be used in large clinical studies and standard clinical laboratories. (C) 2003 Elsevier Science Inc.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available