4.4 Article

Evaluation of the interobserver reproducibility of Gleason grading of prostatic adenocarcinoma using tissue microarrays

Journal

HUMAN PATHOLOGY
Volume 34, Issue 5, Pages 444-449

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/S0046-8177(03)00123-0

Keywords

prostate cancer; grading; Gleason score; interobserver reproducibility; tissue microarray

Categories

Funding

  1. NCI NIH HHS [P50 CA69568] Funding Source: Medline

Ask authors/readers for more resources

The Gleason system is the internationally recognized standard for grading prostate cancer, due mainly to its strong prognostic capability. However, interobserver reproducibility is variable in the community setting. Herein we present a novel approach to evaluating Gleason grading among pathologists using high-density tissue microarrays (TMAs). A CD-ROM containing 537 different TMA spot images of 0.6-mm diameter was sent to 10 genitourinary pathologists in France. The pathologists were expected to score each TMA spot based on their experience evaluating standard prostate biopsies, transurethral resections, and prostatectomy samples. There was no consensus meeting beforehand to agree on how the group would apply the Gleason grading system for this project. Percentage of agreement and kappa value were used to assess the level of agreement. A short questionnaire was sent to assess pathologists' opinion on this new approach to evaluating Gleason grading. An average of 311 images were analyzed (range, 104 to 537; median, 256.5). Four of the pathologists evaluated all 537 images and assigned Gleason grades to 149 images with an overall kappa for interobserver agreement for the exact score between 0.31 and 0.52 and between 0.45 to 0.69 if 3 Gleason categories (less than or equal to6, 7, and >7) were used. When 2 categories were considered (less than or equal to7 or >7), kappa ranged from 0.58 to 0.83. All pathologists analyzed 104 images. Similar results were obtained with an agreement between 0.28 and 0.54 for the 3 Gleason categories. After finishing this test, 90% of genitourinary pathologists considered this approach useful for resident training and 90% for pathology teaching. We conclude that a Gleason score can be easily assigned to each TMA spot of a 0.6-mm-diameter prostate cancer sample. These data also indicated that using TMA spot images may be a good approach for teaching the Gleason grading system due to the small area of tissue. (C) 2003 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available