4.5 Article

A Biomechanical Comparison of 2 Transosseous-Equivalent Double-Row Rotator Cuff Repair Techniques Using Bioabsorbable Anchors: Cyclic Loading and Failure Behavior

Journal

Publisher

W B SAUNDERS CO-ELSEVIER INC
DOI: 10.1016/j.arthro.2009.02.023

Keywords

Double row; Rotator cuff; Suture anchor; Biomechanical testing

Funding

  1. Arthrex, Naples, Florida

Ask authors/readers for more resources

Purpose: A novel double-row configuration was compared with a traditional double-row configuration for rotator cuff repair. Methods: In 10 matched-pair sheep shoulders in vitro repair was performed with either a double-row technique with corkscrew suture anchors for the medial row and insertion anchors for the lateral row (group A) or a double-row technique with a new tape-like suture material with insertion anchors for both the medial and lateral rows (group B). Each specimen underwent cyclic loading from 10 to 150 N for 100 cycles, followed by unidirectional failure testing. Gap formation and strain within the repair area for the first and last cycles were analyzed with a video digitizing system, and stiffness and failure load were determined from the load-elongation curve. Results: The results were similar for the 2 repair types. There was no significant difference between the ultimate failure loads of the 2 techniques (421 +/- 150 N in group A and 408 +/- 66 N in group B, P = .31) or the stiffness of the 2 techniques (84 +/- 26 N/mm in group A and 99 +/- 20 N/mm in group B, P = .07). In addition, gap formation was not different between the repair types. Strain over the repair area was also not different between the repair types. Conclusions: Both tested rotator cuff repair techniques had high failure loads, limited gap formation. and acceptable strain patterns. No significant difference was found between the novel and conventional double-row repair types. Clinical Relevance: Two double-row techniques-one with corkscrew suture anchors for the medial row and insertion anchors for the lateral row and one with insertion anchors for both the medial and lateral rows-provided excellent biomechanical profiles at time 0 for double-row repairs in a sheep model. Although the sheep model may not directly correspond to in vivo conditions, all-insertion anchor double-row constructs are worthy of further investigation.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available